Skip to main content
Reports current

2012 Collaborative Study of CORESTA Monitor #7 (CM7) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained Under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

RAC Final Report

May 2013

The CORESTA Routine Analytical Chemistry Sub Group has been given the responsibility to organize the annual testing of the CORESTA Monitor test piece. The 2012 study was designed to:

  • measure mainstream ISO and Intense smoke yields of nicotine-free dry particulate matter (NFDPM), nicotine and carbon monoxide (CO) to verify the current monitor test piece CM7;
  • determine intra- and inter-laboratory variability for the measured ISO and Intense smoke yields for the CM7;
  • verify the conditioned weight for the CM7.

Related documents

Report - 2019 Collaborative Study of CORESTA Monitor 9 (CM9) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes (August 2020)

Report - 2018 Collaborative Study of CORESTA Monitor 8 (CM8) and 9 (CM9) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes (February 2019)

Report - 2017 Collaborative Study of CORESTA Monitor 8 (CM8) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes (November 2017)

Report - 2016 Collaborative Study of CORESTA Monitor 8 (CM8) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes (February 2017)

Report - 2014-2015 Collaborative Study of CORESTA Monitor Test Pieces CM7 and CM8 for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ Smoking Regime (August 2015)

Report - 2013 Collaborative Study of CORESTA Monitor #7 (CM7) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes (February 2015)

Report - 2011 Collaborative Study of CORESTA Monitors #6 (CM6) and #7 (CM7) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained Under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes (February 2012)

Report - 2010 Collaborative Study of CORESTA Monitor #6 (CM6) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained Under Mainstream “ISO” and “Intense” Smoking Regimes (August 2011)

Report - 2008 Collaborative Study of the CORESTA Monitor Test Piece CM6 for the Determination of Nicotine, NFDPM, Carbon Monoxide and Carbon Dioxide in Sidestream Smoke (August 2010)