Skip to main content
Reports current

2013 Collaborative Study of CORESTA Monitor #7 (CM7) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

RAC Technical Report

February 2015

The CORESTA Routine Analytical Chemistry Sub Group has been given the responsibility to organize the annual testing of the CORESTA Monitor test piece. The 2013 study was designed to:

  • measure mainstream ISO yields of nicotine-free dry particulate matter (NFDPM), nicotine and carbon monoxide (CO) to verify the stability of the current monitor test piece CM7 against previously obtained yields;
  • determine intra- and inter-laboratory variability for the measured ISO and Intense smoke yields for the CM7;
  • verify the conditioned weight for the CM7 against previously obtained weights;
  • measure mainstream smoke yields of nicotine-free dry particulate matter (NFDPM), nicotine and carbon monoxide (CO) under the Health Canada Intense Smoking Regime for laboratory accreditation purposes.

Related documents

Report - 2019 Collaborative Study of CORESTA Monitor 9 (CM9) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

Report - 2018 Collaborative Study of CORESTA Monitor 8 (CM8) and 9 (CM9) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

Report - 2017 Collaborative Study of CORESTA Monitor 8 (CM8) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

Report - 2016 Collaborative Study of CORESTA Monitor 8 (CM8) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

Report - 2014-2015 Collaborative Study of CORESTA Monitor Test Pieces CM7 and CM8 for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained under Mainstream ‘ISO’ Smoking Regime

Report - 2012 Collaborative Study of CORESTA Monitor #7 (CM7) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained Under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

Report - 2011 Collaborative Study of CORESTA Monitors #6 (CM6) and #7 (CM7) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained Under Mainstream ‘ISO’ and ‘Intense’ Smoking Regimes

Report - 2010 Collaborative Study of CORESTA Monitor #6 (CM6) for the Determination of Test Piece Weight, TPM, Water, Nicotine, NFDPM, Carbon Monoxide and Puff Count Obtained Under Mainstream “ISO” and “Intense” Smoking Regimes

Report - 2008 Collaborative Study of the CORESTA Monitor Test Piece CM6 for the Determination of Nicotine, NFDPM, Carbon Monoxide and Carbon Dioxide in Sidestream Smoke