1. CORESTA Congress, Quebec, 2014, Smoke Science/Product Technology Groups, ST 05

    Comparison of Full Length Burn testing according to ISO 12863 and the proposed alternative by NIST Laboratories, USA

    MAYR M.
    Papierfabrik Wattens GmbH & Co. KG / delfortgroup AG, Wattens, Austria
    NIST Laboratories USA proposed to use a thin stainless steel substrate plus one layer of filter paper instead of the 10 layers, as defined in ASTM E.2187-09 and ISO 12863 for measuring the percentage of Full Length Burn on Lower Ignition Propensity (LIP) ...
  2. CORESTA Congress, Quebec, 2014, Smoke Science/Product Technology Groups, ST 08

    CORESTA Recommended Method No. 77

    MAYR M.(1); CORESTA PTM Sub-Group and Diffusivity Working Group Members(2)
    (1) Papierfabrik Wattens GmbH & Co. KG / delfortgroup AG, Wattens, Austria; (2) Various origins
    In 2010, the Physical Test Methods Sub-Group of CORESTA launched the Diffusivity Working Group with the objective to develop a CORESTA Recommended Method (CRM) for the “ Determination of Diffusion Capacity by Measurement of CO2 Transfer Rate Through ...
  3. CORESTA Meeting, Smoke Science/Product Technology, 2013, Seville, ST 46; TSRC, Tob. Sci. Res. Conf., 2013, 67, abstr. 50.

    Impact of using a metal sheet as an “alternative substrate for ISO 12863” on SE performance

    MAYR M.; VIZEE H.
    Papierfabrik Wattens GmbH & Co KG / delfortgroup, Wattens, Austria
    The aim of this study was to demonstrate the impact on SE performance when using different material than filter paper as a possible substrate. NIST proposed to perform these tests on a thin metal sheet (0,2 mm) with one layer of filter paper. As the ISO ...
  4. CORESTA Meeting, Smoke Science/Product Technology, 2013, Seville, ST 53; TSRC, Tob. Sci. Res. Conf., 2013, 67, abstr. 40.

    Comparison of the variability in smoke yield data when smoking cigarette brands onto a 44 mm Cambridge filter pad with a rotary smoking machine

    MAYR M.; CASE P.
    Papierfabrik Wattens GmbH & Co KG / delfortgroup, Wattens, Austria
    The outline of this study was to evaluate the variation of Tar, Nicotine and CO when smoking low yield cigarette brands with a common and a modified Cambridge filter pad holder. Several low yield cigarettes as well as cigarettes with target yields up to ...
  5. TSRC, Tob. Sci. Res. Conf., 2013, 67, abstr. 40

    Comparison of the variability in smoke yield data when smoking cigarette brands onto a 44mm cambridge filter pad with a rotary smoking machine.

    MAYR M.; CASE P.
    delfortgroup/Wattenspapier, Wattens, Austria
    The objective of this study was to evaluate the variation in tar, nicotine and CO when smoking low-yield cigarette brands using a common and a modified Cambridge filter pad holder. Several low yield cigarettes as well as cigarettes with target yields up ...
  6. CORESTA Congress, Sapporo, 2012, Smoke Science/Product Technology Groups, PT 19

    Influence of band width and band material coverage rate (total band area / total paper area) on smoke yields, SE test and free burn

    MAYR M.; VOLGGER D.
    Papierfabrik Wattens GmbH & Co KG, Wattens, Austria
    The objective of this analysis was to evaluate the difference in smoke yields, self-extinguishment performance and free burn rate depending on the different amount of band coverage rate on the FSC cigarette papers. The cigarette base sheet parameters were ...