Bull. Spec. CORESTA Congress, Yokohama, 1996, p. 235, T16
Investigations on the technology of thermal-and-humidity treatment of tobacco
LUDNEV I.
Inst. for Tobacco and Tobacco Products, Plovdiv, Bulgaria
The thermophysical parameters of tobacco heated in bulk with a reduced density of 38,18 - 67,64 kg/m3 were determined. The coefficient of heat conductivity is 0,01975 - 0,0111 W/(m.K). The coefficient of temperature conductivity is 0,269.10-3 -...